FS156-W Incorrect password - CCI Trace is disabled.

Enterprise Test Server V8.0
Rocket® Enterprise Test Server (formerly a product of Micro Focus or formerly a product of Open Text) documentation, created before Rocket Software acquired certain products from OpenText, may include outdated references to "Micro Focus" or "OpenText", both of which are trademarks of OpenText or its affiliates. Rocket Software is not affiliated with Micro Focus or OpenText and has since rebranded these products as Rocket® products. You may also encounter outdated links in this documentation. If you do, please contact Rocket Support (support@rocketsoftware.com) for assistance.

FS156-W Incorrect password - CCI Trace is disabled.

The Fileshare Server has determined that the password entered is incorrect and has consequently disabled the use of the CCI Trace feature.

Resolution:

If CCI Trace is required then the Fileshare Server should be brought down using the Esc key sequence. Ensure that when starting the Fileshare Server the /pf option is used to specify a password file that contains a password for the user-ID FSVIEW. When prompted to enter the supervisor password the password for the FSVIEW user-ID should be entered.

If CCI Trace is not required then no action is required as the Fileshare Server has started and the CCI Trace feature is not enabled. However, to prevent this message in future, the Fileshare Server should be reconfigured not to use CCI Trace.